Implement post-PAR timing analysis #39

Open
azonenberg opened this issue Aug 15, 2016 · 1 comment
Open

Implement post-PAR timing analysis #39

azonenberg opened this issue Aug 15, 2016 · 1 comment

Comments

@azonenberg
Copy link
Owner

Static is preferred, topological would be OK probably. Needs timing data that is not currently released by Silego. Will need to characterize or get them to publish it.

@ArcaneNibble
Copy link
Collaborator

  • <azonenberg_work> [Blinky] has a stateful feedback loop in a fabric-based (vs hard IP) counter <azonenberg_work> but my timing analyzer thinks everything is combinatorial right now <azonenberg_work> it tries to trace D to Q combinatorially